19'' 6U Chassis page 9/71
Installation Manual
Site Preparation.
Before installation ensure that your site meets the following requirements:
Mounting
With the mount kit provided, use a 19in (48.3cm) equipment rack, correctly grounded
and secure.
The MS430502M chassis may also be installed in a 23in or ETSI rack with the aid of
suitable extension brackets.
Access
Locate the MS430502M chassis in a position that allows access to the front panel,
enabling maintenance, connection and visual checking.
Power Source
Provide a suitable power source within 15 feet (5 meters) from the location. The
supplied -48V cables are 5 meters in length. Power specifications can be found in the
technical Specification of the MS430502M chassis.
Environment
Install the MS430502M chassis in a suitable location with an ambient temperature of
0°C to 50°C and a maximum relative humidity of 85%.
Do not allow the air inlets to become obstructed, causing airflow restriction. Keep 1.5
in (4 cm) free on both sides to ensure adequate ventilation.
Delivery
-48V version
Verify the contents of the delivery. The basic delivery should consist of the following:
• One MS430502M 6U subrack, containing:
One Management card (MGNT)
One Fan unit (FAN)
• Two -48V cables
• One Rack-Mount installation kit
• One set of documentation
• One to ten generic slot MS modules
Check your order for site specific equipment, number/type of modules etc. If any items
are missing contact your supplier immediately.