19'' 6U Chassis page 52/71
• Use your SNMP browser to check the backup file presence in the FLASH
memory of the MGNT management board using the table:
• mgnt2CnfManageConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
From this point the maintenance configuration feature is enabled. It means that
if a new MSxxxxxxx module is plugged in the slot number pointed by the backup
file, the MGNT management board will performed the following process:
• Check if the backup file is compatible with the MSxxxxxxx module plugged in
(i.e. same number of line ports and same number of client ports)
• If the compatibility is correct, the backup file configuration will be
automatically transferred to the MSxxxxxxx module.
2. Transferring the backup file
The object of this phase is to transfer the backup file from the FLASH memory to the
RAM memory of the MGNT management board.
• Use your SNMP browser to check the backup file presence in the RAM
memory of the MGNT management board using the table:
• mgnt2CnfUploadConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
There is space to store four configuration files in The RAM memory. At this stage
in the procedure, there should be no file in the RAM memory.
If there is no free space any more in the RAM memory, you may delete a backup
file from the RAM memory using the object:
• mgnt2CnfDeleteConfigFile
Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigF
ilesTable
• Export the backup file previously created in the FLASH memory to the RAM
memory using the object:
mgnt2CnfExportConfig
Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfManageConfig
FilesTable
• Use your SNMP browser to check the backup file presence in the RAM
memory of the MGNT management board using the table:
• mgnt2CnfUploadConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
The backup file is now located in the RAM memory and is accessible via a TFTP
command.
3. Get the backup file
The object of this phase is to get the backup file in the RAM memory of the MGNT
management board.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com