19'' 6U Chassis page 30/71
Name Description Value
API Information Codes
DEF_API_OK Default Value 0
DEF_API_COLD_RESET_MODULE Cold Reset request 4
DEF_API_WARM_RESET_MODULE Warm Reset request 5
DEF_API_DOWNLOAD_IN_PROGRESS Download in Progress 3
API Error Codes
moduleNotResponding
A timeout occurred on requested response of a
command
128
messageFormatError The module has detected a wrong message format 129
cmdExecutionError
Internal module error during the processing of a
message
130
unknownArticleError The article is unknown or not allowed 132
unknownMessageError The message is unknown or not allowed 133
Table :3 API error code.
Control
There are six objects associated with the control function.
Location:...\microsens \mgnt2\mgnt2Hardware\mgnt2controls\
They are responsible for:
mgnt2CtrlGigamixWarmReset
This bit allows resetting the MGNT in a 'warm' manner. A warm reset does not affect
the traffic, the module configuration remains unchanged.
mgnt2CtrlChassisShutDown
This bit must be set to two to shut down the MS430502M chassis in a correct manner.
Once the OID has been set, it is necessary to wait for 5 seconds before removing the
power of the MS430502M chassis.
mgnt2CtrlEthPort2Disable
This bit enables/disables the second Ethernet Port on the MGNT (right port).
When not required it is advised to disable this port in order to avoid unauthorised
connection.
mgnt2CtrlGreenLed
This bit switches ON all the green LEDs of the MS430502M chassis (MGNT, FAN and all
the MS modules plugged in the MS430502M chassis).
mgnt2CtrlRedLed
This bit switches ON all the red LEDs of the MS430502M chassis (MGNT, FAN and all the
MS modules plugged in the MS430502M chassis).
mgnt2CtrlLedOff
This bit switches OFF all the LEDs of the MS430502M chassis (MGNT, FAN and all the MS
modules plugged in the MS430502M chassis).