Microsens RS232 Especificaciones Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 71
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
19'' 6U Chassis page 35/71
Procedure
1. Remote Loading Phase
The object of this phase is to load the software package into the RAM of the
MS430502M chassis MGNT. There are no service implications during this phase.
For this example, the package will be called package1.pak
Preparation
Verify that the package you intend to download into the FLASH is not
already there:
Consult the table: mgnt2DwlPackageTable
Location:...\microsens\mgnt2\mgnt2SoftwareManagement.
This table will list the four packages resident in the FLASH by the object:
mgnt2DwlPackageFileName
And which one is currently being extracted by the object:
mgnt2ExtractedPack
If the package that you intend to load in the FLASH is present in the table and is
currently in use (mgnt2ExtractedPack = "two") you will have to change the name
of the package which you intend to load, otherwise the current package will be
overwritten. E.g. if package1.pak is currently in use rename your file
package2.pak.
When renaming the package ensure that the new name is compliant with the
Unix standard and no more than 24 characters long including the extension.
Use your SNMP browser to perform a table update and check the status of
the RAM using the table:
mgnt2DwlUploadingTable
Location:...\microsens\mgnt2\mgnt2SoftwareManagement
This table lists the packages resident in the RAM by the object:
mgnt2DwlUploadFileName
There can be up to four packages in the RAM, at this stage in the procedure
there should be none.
Open a Command Line Interface window from your operating system and go
to the directory where you placed the new package.
Enter the line (Windows XP):
T:\home\> tftp -i 192.168.16.123 PUT package1.pak /tftpboot/package1.pak
Where: T:\home – is the location of the package on your PC
package1.pak - is the name of the package you wish to upload
192.168.16.123 - is the IP address of the MS430502M chassis into which
the package is to be loaded.
Return of the prompt indicates completion of download.
Update the uploading table:
Set to one the object: mgnt2DwlUploadingTableUpdate