19'' 6U Chassis page 28/71
mgnt2AlmMsSlot6Absent
MS present in Chassis slot 6:
This OID indicates the presence of a MS
modulein Slot 6 of the Chassis.
Verify correct
configuration.
mgnt2AlmMsFanAbsent
FAN module present in Chassis:
This OID indicates the presence of the FAN
module in the Chassis
Insert a FAN in the
MS430502M chassis
mgnt2AlmPbFan1Fail
Fan unit n°1 failed on Fan module:
This OID indicates a failure on fan 1.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmPbFan2Fail
Fan unit n°2 failed on Fan module:
This OID indicates a failure on fan 2.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmPbFan3Fail
Fan unit n°3 failed on Fan module:
This OID indicates a failure on fan 3.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmPbFan4Fail
Fan unit n°4 failed on Fan module:
This OID indicates a failure on fan 4.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmPbFan5Fail
Fan unit n°5 failed on Fan module:
This OID indicates a failure on fan 5.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmPbFan6Fail
Fan unit n°6 failed on Fan module:
This OID indicates a failure on fan 6.
Removal of the fan unit or no rotation sets
the OID.
Replace the Fan Unit
mgnt2AlmFanPwrProtOn
Fan Backup Power :This OID indicates the
backup power on the FAN module is
switched on
Replace the Fan Unit
mgnt2AlmFanPwrFail1
Fan Main Power:
This OID indicates a failure on the main
power of the FAN module
Correlate all alarms. If
Alarm persists change the
module.
mgnt2AlmFanDefFuseA
Fan Fuse A fail:
This OID indicates that the fuse of the
power input A is in fail condition on he Fan
board
Correlate all alarms. If
Alarm persists change the
module.
mgnt2AlmFanDefFuseB
Fan Fuse B Fail:
This OID indicates that the fuse of the
power input B is in fail condition on the Fan
board
Correlate all alarms. If
Alarm persists change the
module.
mgnt2AlmApiError
Comm fail between Agent and MSs :
This OID indicates a failure detected on the
Agent.The failure is located on a
communication process with the modules.
-Correlate other alarms
and Traps.
-Reset the Management
board.
mgnt2AlmFifoCmdError
SNMP Agent to MS modulecomm FIFO fail:
This OID indicates a failure inside the FIFO
stack. The FIFO containing the messages
from the agent (write) to the MSs is full
-Correlate other alarms
and Traps.
-Reset the Management
board.
mgnt2AlmApiErrorCode
API Error Identification:
Error number and description of the
abs1AlmApiError object
See API error table
mgnt2AlmLogFileFull Log File Full Alarm:
This OID indicates that a log file is full. This
Reset the log file to insure
correct working of the log
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com