19'' 6U Chassis page 23/71
Automatic with DIP switches
The MS430502M chassis MGNT Management Board is equipped with 8 DIP
switches that may be used to define the MS430502M chassis IP Address. The
following picture gives the location of these DIP switches on the Board.
Figure 13: MGNT Board top view
The DIP switch can be used to set the last byte of the MS430502M chassis IP
Address. The right switch is the Most Signficant Byte of the byte and the left
switch is the Least Significant Byte of the byte. For each switch, the top position
represents a 1 and bottom position represents a 0.
In the previous picture, the DIP switches define a value of 108 (0x6C). The
automatic IP address configuration by DIP switch procedure is carried out in two
phases:
1. Define the IP Address map (the three first bytes of the IP address).
2. Configure the DIP switches to set the last byte of the IP address.
Described in more details as follows:
Procedure
1. Define the IP Address map
Use the default MS430502M chassis IP address to get access to the SNMP
agent
Set the object
mgnt2GigmBoardIpAddress
Location: ...\microsens\mgnt2\mgnt2SNMPAgentData\ mgnt2IPmanagment
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com