19'' 6U Chassis page 71/71
the Mgnt2 management
module
1.3.6.1.4.1.20044.7.3.1 mgnt2TrapApi n/a
Api error trap with its
number
1.3.6.1.4.1.20044.7.3.2 mgnt2TrapSwError n/a
Chassis software error
other API
1.3.6.1.4.1.20044.7.3.4 mgnt2TrapBoardInserted n/a
A board has been
plugged in
1.3.6.1.4.1.20044.7.3.5 mgnt2TrapBoardRemoved n/a
A board has been
plugged out
1.3.6.1.4.1.20044.7.3.6 mgnt2TrapRestoreConfDone n/a
The Configuration has
been restored from the
management board
1.3.6.1.4.1.20044.7.3.8 mgnt2TrapGlobalPowerFail n/a
A global power supply
failure has been detected
1.3.6.1.4.1.20044.7.3.9 mgnt2TrapFanPowerFail n/a
A Fan power supply
failure has been detected
1.3.6.1.4.1.20044.7.3.10 mgnt2TrapGigmPowerFail n/a
A power supply default
has been detected in the
management board
1.3.6.1.4.1.20044.7.3.11 mgnt2TrapFanFail n/a
A Fan failure has been
detected
1.3.6.1.4.1.20044.7.3.20 mgnt2TrapLogFileFull n/a
Indicates that the
corresponding log file is
almost full
Technical Specifications
Type
19“ Chassis 6 HU, 5 module slots, incl. Backplane
Power cosumption
32.5 W typical without MS modules in generic slots
Operating temperature
0°C to 50°C
Storage temperature
-20°C to +70°C
Humidity
5-85%
Order Information
Chassis
MS430502M
19“ Chassis 6 HU, 5 module slots, 2x 48 VDC
power supplies, incl. Backplane
MICROSENS reserves the right to make any changes without further notice to any product to improve reliability,
function or design. MICROSENS does not assume any liability arising out of the application or use of any product.
tn/2007
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com