19'' 6U Chassis page 13/71
MGNT boards are shipped with the Agent software loaded. Note the version
required on your site in the case where the replacement board needs to be
upgraded follow the procedure: SNMP Agent Update outlined in the MS430502M
chassis user manual.
• Verify that the wrist strap you are wearing is properly grounded or that
other antistatic measures are in place
• Disconnect any Ethernet cables from the Rj45 sockets on the front of the
board
• Using a flat head screwdriver loosen the two holding screws on the front
plate, located at the top right-hand and bottom right-hand corners
• Slide the MGNT Board out of the chassis, unplugging the backplane
connectors,and set aside
• Line up the replacement MGNT Management Board with the lower rail and
gently slide it in, plugging in the backplane connectors
• Using a flat head screwdriver; tighten the two holding screws on the front
plate located at the top right-hand and bottom right-hand corners:
• Re-connect Ethernet cables to the RJ-45 sockets on the front panel
• Observe behaviour of LEDs
• Perform a full inventory on the MGNT management board using the objects:
mgnt2RinvHwPlatform
mgnt2RinvSoftwarePackage
mgnt2RinvGateware
mgnt2RinvAgent
Location: ...\microsens\mgnt2\mgnt2RemoteInventor
• Reload Software if required using the procedure outlined in the MS430502M
chassis user manual
• Verify status of MGNT Board
• Verify communication with module(s)
• Re-integrate the MS430502M chassis into your network
End procedure
Rescue CLI mode
The rescue CLI can be launched in case of major software crash on the MGNT board to
retrieve a working software. When the rescue CLI is activated, the following
parameters are restored to their default value:
Parameter Default value
SNMP communities
SNMP Get: public
SNMP Set: private
SNMP Trap: public
CLI passwords
administrator: administrator
maintenance: maintenance
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com