Media Converter/Signal Repeater page 25/29
OID Name Access Description
1.3.6.1.4.1.20044.21.2.3.2.26.15 ms430580mAlmLine2RxPwrLowAla r TRSCV 2 Rx Power Low: Alarm
indicating that the transceiver input
power of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.16 ms430580mAlmLine2RxPwrHighAla r TRSCV 2 Rx Power High: Alarm
indicating that the transceiver input
power of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.3 ms430580mAlmLineCrit
1.3.6.1.4.1.20044.21.2.3.3.7 ms430580mAlmsynthAlm7
1.3.6.1.4.1.20044.21.2.3.3.7.1 ms430580mAlmLine2TrscvAbsent r Line 2 SFP not plugged: This OID
indicates that the transceiver
module 2 is not present.
1.3.6.1.4.1.20044.21.2.3.3.7.2 ms430580mAlmLine2TrscvDdmAbsent r DDM supported on Line 2 SFP: This
OID indicates that the transceiver
module 2 does not support Digital
Diagnostic Monitoring Functions
1.3.6.1.4.1.20044.21.2.3.3.7.4 ms430580mAlmLine2HwFail r Line 2 HW Failure: This OID indicates
a hardware failure on the Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.5 ms430580mAlmLine2TrscvLsd r Line 2 SFP optical TX ON :This OID
indicates the optical output power
is off on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.9 ms430580mAlmLine2TrscvDdmWarning r Warning DDM on Optical Module 2:
This OID indicates a warning is
present coming out of optical
interface DDM on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.10 ms430580mAlmLine2TrscvDdmAlm r Alarm DDM on Optical Module 2:
This OID indicates an alarm is
present coming out of optical
interface DDM on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.12 ms430580mAlmLine2Fail r Line 2 Failure: This OID indicates a
failure on the Line 2
1.3.6.1.4.1.20044.21.2.3.3.24 ms430580mAlmline2AccessioAlm
1.3.6.1.4.1.20044.21.2.3.3.24.1 ms430580mAlmLine2LasFail r Line 2 SFP Tx Failed :This OID
indicates that the transmitter fails
for the transceiver plugged into the
Line 1 (this alarm reports the
transmitter failure alarm generated
by the transceivers)
1.3.6.1.4.1.20044.21.2.3.3.24.4 ms430580mAlmLine2Los r Loss of Optical signal on Line 2 :This
OID indicates that no signal is
present on the transceiver 2
1.3.6.1.4.1.20044.21.3 ms430580mmeasures
1.3.6.1.4.1.20044.21.3.1 ms430580mMesrOther
1.3.6.1.4.1.20044.21.3.2 ms430580mMesrClient
1.3.6.1.4.1.20044.21.3.2.16 ms430580mMesrline1Temperature r Line 1 SFP Temperature :This OID
gives the temperature of the
transceiver Line 1, read from the
DDM (Digital Diagnostic
Monitoring) (Unit = °C)
1.3.6.1.4.1.20044.21.3.2.17 ms430580mMesrline1Volt r Line 1 SFP Power Supply: This OID
gives the voltage of the transceiver
Line 1, read from the DDM (Digital
Diagnostic Monitoring) (Unit = V)