Media Converter/Signal Repeater page 21/29
Power in dBm or mW can be obtained by applying the following formula to the
returned value:
Rx_Pwr(mW) = AV/10000
Rx_Pwr(dBm) = 10xlog(AV/10000)
Parameter Meaning Format
AV Article Value Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaRxPower outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaRxPower (integer) 10
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 10.
So applying the formula: Rx_Pwr(mW) = 10/10000
Gives an actual value of: 0.001mW
And applying the formula: Rx_Pwr(dBm) = 10xlog(10/10000)
Gives an actual value of: -30dBm
Appendixes
Laser Class
Laser Class Risks General Requirements
1
Considered safe to eye and Skin under
all reasonably foreseeable conditions
of operation.
Protective housing: may be
required.
MS430580M Leds description
LED Status Condition
SW Green On Normal
Red On Init/ReBoot
HW Green On Normal
Red On Init./Reboot
Line 1 Los Green Normal
Red Line 1 Loss of Signal
Line 1 Fail Green Normal
Red Line 1 Failure
Line 2 Los Green Normal
Red Line 2 Loss of Signal
Line 2 fail Green Normal
Red Line 2 Failure