NAME DESCRIPTION ACTION
ms430580mAlmLine2Fail Line 2 Failure: This OID
indicates a failure on the Line 2
Correlate relevant alarms. Carry
out necessary maintenance
procedures.
ms430580mAlmLine2LasFail Line 2 SFP Tx Failed: This OID
indicates that the transmitter
fails for the transceiver plugged
into the Line 1 (this alarm
reports the transmitter failure
alarm generated by the
transceivers)
Correlate relevant alarms. If
Alarm
persists replace the Client SFP.
ms430580mAlmLine2Los Loss of Optical signal on Line 2:
This OID indicates that no
signal is present on the
transceiver 2
Check client status. Carry out
necessary maintenance
procedures.
Traps
A trap is an unsolicited, asynchronous event that the MGNT generates to indicate a
status change; e.g.: a trap is generated on the detection of a start of an alarm and an
end of an alarm.
Note
It is important to set the IP address of t he manager correctly in order to receive
the traps.
There are two types of trap:
• Line 1 traps originating from Line 1 problems.
• Line 2 traps originating from Line 2 problems.
These are further categorised as follows:
• Critical: –Traffic affecting, demanding immediate attention.
• Urgent: –Indicating that maintenance is required.
• Non-urgent: – Warning, information, non traffic affecting origin DDM.
The binding information that accompanies a trap is for information only and should be
used to make the alarm polling more efficient.
The following table lists the possible traps originating from a MS430580M and their
contributing alarms.