NAME DESCRIPTION ACTION
ms430580mAlmLine1RxPwrHighAla TRSCV 1 Rx Power High: Alarm
indicating that the transceiver
input power of Line 1 is higher
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TrscvAbsent Line 1 SFP not plugged: This
OID indicates that the
transceiver module 2 is not
present.
Plug in the Optical Module. If
Alarm
persists change the optical
component.
ms430580mAlmLine1TrscvDdmAbsent DDM supported on Line 1 SFP:
This OID indicates that the
transceiver module 1 does not
support Digital Diagnostic
Monitoring Functions
If SFP supports DDM change the
SFP, else ignore.
ms430580mAlmLine1HwFail Line 1 HW Failure: This OID
indicates a hardware failure on
the Line 1
Correlate relevant alarms. Carry
out
necessary maintenance
procedures.
ms430580mAlmLine1TrscvLsd Line 1 SFP optical TX ON: This
OID indicates the optical output
power is off on Line 1
No action information only.
ms430580mAlmLine1TrscvDdmWarning Warning DDM on Optical
Module 1: This OID indicates a
warning is present coming out
of optical interface DDM on
Line 1
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TrscvDdmAlm Alarm DDM on Optical Module
1: This OID indicates an alarm is
present coming out of optical
interface DDM on Line 1
Correlate all alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1Fail Line 1 Failure: This OID
indicates a failure on the Line 1
Correlate relevant alarms. Carry
out necessary maintenance
procedures.
ms430580mAlmLine1LasFail Line 1 SFP Tx Failed: This OID
indicates that the transmitter
fails for the transceiver plugged
into the Line 1 (this alarm
reports the transmitter failure
alarm generated by the
transceivers)
Correlate relevant alarms. If
Alarm
persists replace the Client SFP.
ms430580mAlmLine1Los Loss of Optical signal on Line 1:
This OID indicates that no signal
is present on thetransceiver 1
Check client status. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TxPwLowWng TRSCV 2 Tx Power Low warning:
Warning indicating that the
transceiver output power of
Line 2 is lower than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TxPwrHighWng TRSCV 2 Tx Power High
warning :Warning indicating
that the transceiver output
power of Line 2 is higher than
the threshold value written in
the transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.