OID Name Access Description
1.3.6.1.4.1.20044.21.2.2.3.8.1 ms430580mAlmLine1TrscvAbsent r Line 1 SFP not plugged :This OID
indicates that the transceiver module 2 is
not present.
1.3.6.1.4.1.20044.21.2.2.3.8.2 ms430580mAlmLine1TrscvDdmAbsent r DDM supported on Line 1 SFP :This OID
indicates that the transceiver module 1
does not support Digital Diagnostic
Monitoring Functions
1.3.6.1.4.1.20044.21.2.2.3.8.4 ms430580mAlmLine1HwFail r Line 1 HW Failure :This OID indicates a
hardware failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.5 ms430580mAlmLine1TrscvLsd r Line 1 SFP optical TX ON :This OID
indicates the optical output power is off
on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.9 ms430580mAlmLine1TrscvDdmWarning r Warning DDM on Optical Module 1: This
OID indicates a warning is present
coming out of optical interface DDM on
Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.10 ms430580mAlmLine1TrscvDdmAlm r Alarm DDM on Optical Module 1: This
OID indicates an alarm is present coming
out of optical interface DDM on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.12 ms430580mAlmLine1Fail r Line 1 Failure: This OID indicates a
failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.16 ms430580mAlmline1AccessioAlm
1.3.6.1.4.1.20044.21.2.2.3.16.1 ms430580mAlmLine1LasFail r Line 1 SFP Tx Failed: This OID indicates
that the transmitter fails for the
transceiver plugged into the Line 1 (this
alarm reports the transmitter failure
alarm generated by the transceivers)
1.3.6.1.4.1.20044.21.2.2.3.16.4 ms430580mAlmLine1Los r Loss of Optical signal on Line 1: This OID
indicates that no signal is present on the
transceiver 1
1.3.6.1.4.1.20044.21.2.3 ms430580mAlmLine
1.3.6.1.4.1.20044.21.2.3.1 ms430580mAlmLineNurg
1.3.6.1.4.1.20044.21.2.3.1.28 ms430580mAlmline2TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.3.1.28.1 ms430580mAlmLine2TxPwLowWng r TRSCV 2 Tx Power Low warning:
Warning indicating that the transceiver
output power of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.2 ms430580mAlmLine2TxPwrHighWng r TRSCV 2 Tx Power High warning:
Warning indicating that the transceiver
output power of Line 2 is higher than
the threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.3 ms430580mAlmLine2TxBiasLowWng r TRSCV 2 Bias Low warning: Warning
indicating that the transceiver laser bias
current of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.4 ms430580mAlmLine2TxBiasHighWng r TRSCV 2 Bias High warning :Warning
indicating that the transceiver laser bias
current of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.7 ms430580mAlmLine2TempLowWng r TRSCV 2 Temp Low warning:Warning
indicating that the transceiver
temperature of Line 2 is lower than the
threshold value written in the
transceiver EEPROM