MICROSENS User Manual Device Server RS-232/422/485 Port to 1x or 2x 10/100TX
and Device Server RS-232/422/485 Port to 1x 100FX
Port Serial Setting
Port Configuration includes Serial Setting, Port Profile and Service Mode.
Serial Setting
Port page
This page allows user to assign Serial Setting parameters, such as baud rate, data bits,
stop bits, parity, and flow control etc.
Port Alias: Give an alias name to the port to hint the connected device.
Interface: 4 type for selecting–RS232 / RS422 / RS485 (2-wires) / RS485 (4-wires)
Baud rate: It’s in the range of 110bps to 460800bps.
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 2 (1.5)
Parity: No, Even, Odd, Mark, Space
Flow Control: No, XON/XOFF, RTS/CTS, DTR/DSR
Force TX Interval Time: Force TX interval time is to specify the timeout when no
data has been transmitted. When the timeout is reached or TX buffer is full (4K Bytes),
the queued data will be sent. Zero means disable (factory default).