4 Port Industrial Device Server Manual page 20/36
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
The following table describes the labels in this screen.
Label
Description
Destination Host
Set the IP address of host.
Port
Set the port number of data port.
Idle Timeout
When serial port stops data transmission for a defined period of time
(Idle Timeout), the connection will be closed and the port will be freed
and try to connect with other hosts. 0 indicate disable this function.
Factory default value is 0. If Multilink is configured, only the first host
connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined
time interval (Alive Check) to remote host to check the TCP
connection. If the TCP connection is not alive, the connection will be
closed and the port will be freed. 0 indicate disable this function.
Factory default is 0.
Connect on Startup
The TCP Client will build TCP connection once the connected serial
device is started.
Connect on Any
Character
The TCP Client will build TCP connection once the connected serial
device starts to send data.
Service Mode UDP Mode
Compared to TCP communication, UDP is faster and more efficient. In UDP mode,
you can Uni-cast or Multi-cast data from the serial device server to host computers,
and the serial device can also receive data from one or multiple host.